Blondel
OMNIBUILDING · CONSTRUCTION & DIY

Stair Calculator: Rise, Run & Blondel Formula

Calculate number of steps, rise, run and total stringer length with comfort and building code compliance check (2R + T = 24–25 in / 62–64 cm) and IRC/IBC standards.

1

STAIR DIMENSIONS, RISE & PARAMETERS

in
in
Quick Standard Presets:
2

RESULTS, BLONDEL'S FORMULA VERIFICATION & GRAPHIC SCHEMA

Calculated Riser (R) 7.2 in IRC Max: 7.75 in
Calculated Tread (T) 11.0 in IRC Min: 10.0 in
Total Steps / Risers 15 Total Risers
Blondel (2R + T) 25.4 in Target: 24 – 25.5 in
✓

Optimal Comfort & Code Compliant

Perfect

The staircase matches the golden Blondel comfort rule (2R + T between 24 and 25.5 in) with easy ascending rhythm.

Interactive Blueprint Section Dynamic vector scale
H: 108 in L: 154 in (14 treads) 15 risers of 7.2 in • 11.0 in tread • 33.2°
Blondel's Rule: 2 × Riser + Tread = 24 ÷ 25.5 in (62 ÷ 64 cm). Twice the riser plus the tread matches human natural gait without straining leg joints.

Stair Dimensional Standards & Blondel Comfort Guidelines

Stair Application Building Code Riser (R) Tread (T) 2R + T Verification
Commercial & Public Buildings IBC Section 1011 ≤ 7.0 in (17.8 cm) ≥ 11.0 in (27.9 cm) 25.0 in (Optimal)
Residential Interior (IRC) IRC Section R311.7 ≤ 7.75 in (19.7 cm) ≥ 10.0 in (25.4 cm) 24.5 – 25.5 in (Ideal)
Lofts / Attic Access Stairs IRC Alternate Means 7.5 – 8.25 in 9.0 – 9.75 in 24.0 in (Steep)
Exterior Garden & Porch Stairs Landscape Architectural Std 5.5 – 6.5 in 12.0 – 14.0 in 25.0 in (Gentle)

Frequently Asked Questions about Stair Rise, Run & Blondel Formula

What is Blondel's formula for stair comfort?
Architect François Blondel established that the biomechanical relationship for walking up stairs without fatigue is: 2 × Riser + 1 × Tread = 24 ÷ 25.5 inches (62 ÷ 64 cm) (ideal value 25 inches / 63 cm). This reproduces a person's natural horizontal stride length.
What are standard residential rise and run dimensions according to the IRC?
Under the International Residential Code (IRC Section R311.7), the maximum riser height is 7.75 inches (19.7 cm) and the minimum tread depth is 10.0 inches (25.4 cm) with at least a 3/4-in nosing (or 11.0 in without nosing).
How many vertical feet or risers can you build before needing a landing?
Building safety codes (IRC & IBC) require a rest landing for every 12 feet (144 inches or approx. 18 risers) of vertical rise. The landing length in the direction of travel must be at least equal to the stair width (typically 36 inches minimum).
What is the ideal angle of incline for comfortable stairs?
The optimal angle of inclination for interior residential stairs is between 30° and 37°. Steeper stairs exceeding 42° become hazardous to descend, while slopes under 26° act more like stepped ramps.